A vulnerability classified as critical was found in Siemens Solid Edge up to 224.0 Update 1. This vulnerability affects unknown code of the component PAR File Handler. The manipulation leads to stack-based buffer overflow.
This vulnerability was named CVE-2024-34773. The attack can be initiated remotely. There is no exploit available.
It is recommended to apply a patch to fix this issue.
A vulnerability was found in Siemens CPC80 Central Processing Communication and CPCI85 Central Processing Communication. It has been classified as critical. This affects an unknown part of the component HTTP Header Handler. The manipulation leads to improper null termination.
This vulnerability is uniquely identified as CVE-2024-31484. It is possible to initiate the attack remotely. Furthermore, there is an exploit available.
It is recommended to upgrade the affected component.
A vulnerability was found in Siemens Parasolid. It has been declared as critical. This vulnerability affects unknown code of the component X_T File Handler. The manipulation leads to out-of-bounds write.
This vulnerability was named CVE-2024-31980. The attack can be initiated remotely. There is no exploit available.
It is recommended to upgrade the affected component.
A vulnerability was found in Siemens PS IGES Parasolid Translator Component. It has been rated as critical. This issue affects some unknown processing of the component IGS File Handler. The manipulation leads to out-of-bounds read.
The identification of this vulnerability is CVE-2024-32055. The attack may be initiated remotely. There is no exploit available.
It is recommended to upgrade the affected component.
A vulnerability classified as very critical has been found in Siemens PS IGES Parasolid Translator Component. Affected is an unknown function of the component IGS File Handler. The manipulation leads to type confusion.
This vulnerability is traded as CVE-2024-32057. It is possible to launch the attack remotely. There is no exploit available.
It is recommended to upgrade the affected component.
A vulnerability was found in Mozilla Firefox up to 50. It has been rated as critical. Affected by this issue is some unknown functionality of the component DOM Event Handler. The manipulation leads to use after free.
This vulnerability is handled as CVE-2016-9899. The attack may be launched remotely. Furthermore, there is an exploit available.
It is recommended to upgrade the affected component.
A vulnerability classified as critical was found in Siemens PS IGES Parasolid Translator Component. Affected by this vulnerability is an unknown functionality of the component IGS File Handler. The manipulation leads to memory corruption.
This vulnerability is known as CVE-2024-32058. The attack can be launched remotely. There is no exploit available.
It is recommended to upgrade the affected component.
A vulnerability, which was classified as critical, has been found in Siemens PS IGES Parasolid Translator Component. Affected by this issue is some unknown functionality of the component IGS File Handler. The manipulation leads to out-of-bounds read.
This vulnerability is handled as CVE-2024-32060. The attack may be launched remotely. There is no exploit available.
It is recommended to upgrade the affected component.
A vulnerability, which was classified as critical, was found in Siemens PS IGES Parasolid Translator Component. This affects an unknown part of the component IGS File Handler. The manipulation leads to out-of-bounds read.
This vulnerability is uniquely identified as CVE-2024-32061. It is possible to initiate the attack remotely. There is no exploit available.
It is recommended to upgrade the affected component.
A vulnerability has been found in Siemens PS IGES Parasolid Translator Component and classified as critical. This vulnerability affects unknown code of the component IGS File Handler. The manipulation leads to out-of-bounds read.
This vulnerability was named CVE-2024-32059. The attack can be initiated remotely. There is no exploit available.
It is recommended to upgrade the affected component.
A vulnerability was found in Siemens PS IGES Parasolid Translator Component and classified as critical. This issue affects some unknown processing of the component IGS File Handler. The manipulation leads to type confusion.
The identification of this vulnerability is CVE-2024-32062. The attack may be initiated remotely. There is no exploit available.
It is recommended to upgrade the affected component.
A vulnerability classified as critical was found in Libextractor 0.5.13. Affected by this vulnerability is the function parse_trak_atom. The manipulation leads to heap-based buffer overflow.
This vulnerability is known as CVE-2006-2458. The attack can be launched remotely. Furthermore, there is an exploit available.
It is recommended to upgrade the affected component.
A vulnerability, which was classified as critical, has been found in itsourcecode/code-projects College Management System 1.0. This issue affects some unknown processing of the file /College/admin/teacher.php of the component PHP File Handler. The manipulation leads to privilege escalation.
The identification of this vulnerability is CVE-2022-32420. The attack may be initiated remotely. There is no exploit available.
A vulnerability classified as problematic has been found in Moxa SoftCMS up to 1.5. Affected is an unknown function of the component Web Server. The manipulation leads to improper resource management.
This vulnerability is traded as CVE-2016-9332. It is possible to launch the attack remotely. Furthermore, there is an exploit available.
It is recommended to upgrade the affected component.