A vulnerability, which was classified as critical, was found in DrayTek Vigor2960 and Vigor300B 1.5.1.4. Affected is an unknown function of the file /cgi-bin/mainfunction.cgi/apmcfgupload of the component Web Management Interface. The manipulation of the argument session leads to os command injection.
This vulnerability is traded as CVE-2024-12987. It is possible to launch the attack remotely. Furthermore, there is an exploit available.
It is recommended to upgrade the affected component.
A vulnerability, which was classified as critical, has been found in DrayTek Vigor2960 and Vigor300B 1.5.1.3/1.5.1.4. This issue affects some unknown processing of the file /cgi-bin/mainfunction.cgi/apmcfgupptim of the component Web Management Interface. The manipulation of the argument session leads to os command injection.
The identification of this vulnerability is CVE-2024-12986. The attack may be initiated remotely. Furthermore, there is an exploit available.
It is recommended to upgrade the affected component.
A vulnerability classified as critical was found in Overtek OT-E801G OTE801G65.1.1.0. This vulnerability affects unknown code of the file /diag_ping.cmd?action=test&interface=ppp0.1&ipaddr=8.8.8.8%26%26cat%20/etc/passwd&ipversion=4&sessionKey=test. The manipulation leads to os command injection.
This vulnerability was named CVE-2024-12985. The attack can be initiated remotely. Furthermore, there is an exploit available.
The vendor was contacted early about this disclosure but did not respond in any way.
It is recommended to apply restrictive firewalling.
The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability classified as problematic has been found in Amcrest IP2M-841B, IP2M-841W, IPC-IP2M-841B, IPC-IP3M-943B, IPC-IP3M-943S, IPC-IP3M-HX2B and IPC-IPM-721S up to 20241211. This affects an unknown part of the file /web_caps/webCapsConfig of the component Web Interface. The manipulation leads to information disclosure.
This vulnerability is uniquely identified as CVE-2024-12984. It is possible to initiate the attack remotely. Furthermore, there is an exploit available.
The vendor was contacted early about this disclosure but did not respond in any way.
It is recommended to apply restrictive firewalling.