A vulnerability classified as critical has been found in Mediahouse Statistics Server 4.28/5.1. Affected is an unknown function. The manipulation of the argument Server ID leads to memory corruption.
This vulnerability is traded as CVE-1999-0931. It is possible to launch the attack remotely. Furthermore, there is an exploit available.
It is recommended to upgrade the affected component.
A vulnerability classified as problematic has been found in Apple tvOS up to 11.1. Affected is an unknown function of the component Kernel. The manipulation leads to information disclosure.
This vulnerability is traded as CVE-2017-13865. An attack has to be approached locally. Furthermore, there is an exploit available.
It is recommended to upgrade the affected component.
A vulnerability was found in xine xine-lib 0.9.13/1.0/1.0.1/1.0.2/1.1.0. It has been rated as critical. This issue affects the function fprintf of the file input_cdda.c. The manipulation leads to memory corruption.
The identification of this vulnerability is CVE-2005-2967. The attack may be initiated remotely. Furthermore, there is an exploit available.
It is recommended to upgrade the affected component.
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been rated as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow.
The identification of this vulnerability is CVE-2024-3907. The attack may be initiated remotely. Furthermore, there is an exploit available.
The vendor was contacted early about this disclosure but did not respond in any way.
The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability classified as critical has been found in Tenda AC500 2.0.1.9(1307). Affected is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to command injection.
This vulnerability is traded as CVE-2024-3908. It is possible to launch the attack remotely. Furthermore, there is an exploit available.
The vendor was contacted early about this disclosure but did not respond in any way.
The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability classified as problematic was found in Microsoft Edge on Android. This vulnerability affects unknown code. The manipulation leads to exposure of private personal information to an unauthorized actor.
This vulnerability was named CVE-2024-29986. The attack can be initiated remotely. There is no exploit available.
It is recommended to upgrade the affected component.
A vulnerability, which was classified as problematic, has been found in Microsoft Edge. This issue affects some unknown processing. The manipulation leads to information disclosure.
The identification of this vulnerability is CVE-2024-29987. The attack may be initiated remotely. There is no exploit available.
It is recommended to upgrade the affected component.
A vulnerability classified as critical has been found in Microsoft Edge. This affects an unknown part. The manipulation leads to code injection.
This vulnerability is uniquely identified as CVE-2024-29991. It is possible to initiate the attack remotely. There is no exploit available.
It is recommended to upgrade the affected component.
A vulnerability, which was classified as problematic, was found in Net-SNMP up to 5.9.1. Affected is the function NET-SNMP-AGENT-MIB::nsLogTable of the component OID Handler. The manipulation leads to null pointer dereference.
This vulnerability is traded as CVE-2022-24808. Access to the local network is required for this attack. There is no exploit available.
It is recommended to upgrade the affected component.
A vulnerability has been found in Net-SNMP up to 5.9.1 and classified as problematic. Affected by this vulnerability is the function nsVacmAccessTable of the component OID Handler. The manipulation leads to null pointer dereference.
This vulnerability is known as CVE-2022-24809. Access to the local network is required for this attack to succeed. There is no exploit available.
It is recommended to upgrade the affected component.